Part Number Hot Search : 
BD135 IRFP351 EPF8041 SM220FL IL208AT 75XKCT NTE105 MC74LVX
Product Description
Full Text Search
 

To Download TRCE03KE2C000C3 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  an oplink company oc-3 1510nm optical supervisory channel sfp transceiver TRCE03KE2C000C3 the TRCE03KE2C000C3 sfp fber optic transceiver with integrated digital diagnostics monitoring functionality provides a quick and reliable interface for optical supervisory channel applications. the diagnostic functions, alarm and warning features as described in the multi-source agreement (msa) document, sff-8472 (rev. 9.4), are provided via an i 2 c serial interface. the TRCE03KE2C000C3 transceiver uses a 1510nm dfb laser and an apd receiver to provide an optical link power budget of 44db. the transceiver satisfes class i laser safety requirements in accordance with the u.s. fda/cdrh and international iec-60825 standards. the transceiver connects to a standard 20-pad connector for hot plug capability. this allows the system designer to make confguration changes or maintenance by simply plugging in diferent types of transceivers without removing the power supply from the host system. the transceiver has a blue bail-type latch, which ofers an easy and convenient way to release the module. the latch is compliant with the sfp msa. the transmitter and receiver data interfaces are ac coupled internally. lv-ttl transmitter disable control input and loss of signal output interfaces are also provided. the transceiver operates from a single +3.3v power supply over an operating case temperature range of -5c to +70c (com). the housing is made of metal for emi immunity. product description ? 1510nm dfb transmitter and apd receiver ? 44db link budget ? compatible with sfp msa ? designed for sonet oc-3 (156mb/s) osc application ? digital diagnostics through serial interface ? internal calibration for digital diagnostics ? eye safe (class i laser safety) ? duplex lc optical interface ? excellent emi & esd protection ? hot-pluggable features parameter symbol minimum maximum units storage temperature t st - 40 + 85 c operating case temperature 1 t op - 5 +70 c supply voltage v cc 0 + 5.0 v maximum input optical power p in, max - + 3.0 dbm input voltage v in 0 v cc v 1 measured on top side of sfp module at the front center vent hole of the cage. absolute maximum ratings 21737-0972, rev.a 2009-01-14
laser safety: all transceivers are class i laser products per fda/cdrh and iec-60825 stan- dards. they must be operated under specifed operating conditions. oplink communications, inc. date of manufacture: manufactured in the usa this product complies with 21 cfr 1040.10 and 1040.11 meets class i laser safety requirements oplink communications, in c. transmitter performance characteristics TRCE03KE2C000C3 (over operating case temperature. v cc = 3.13 to 3.47v) parameter symbol minimum typical maximum units operating data rate 1 b - 156 - mb/s average optical output power (coupled into single mode fber), 50% duty cycle p o + 1.0 - + 5.0 dbm extinction ratio p hi /p lo 10 - - db center wavelength 1504.5 1510 1517.5 nm spectral width (-20db) ? - - 1.0 nm side mode suppression ratio smsr 30 - - db optical output eye compliant with telcordia gr-253-core and itu-t recommendation g.957 1 data rate ranges from 50mb/s to 266mb/s. however, some degradation may be incurred in overall performance. receiver performance characteristics parameter symbol minimum typical maximum units operating data rate 1 b - 156 - mb/s receiver sensitivity (10-10 ber) 2 p min -43.0 - - dbm maximum input optical power (10 -12 ber) 2 p max -7.0 0 - dbm los thresholds increasing light input p los+ - - -43.0 dbm decreasing light input p los- -50.0 - - los hysteresis - 0.5 - - db los timing delay increasing light input t_loss_of - - 100 s decreasing light input t_loss_on 2.3 - 100 wavelength of operation 1100 - 1600 nm receiver refectance - - - -25.0 db 1 data rate ranges from 50mb/s to 266mb/s. however, some degradation may be incurred in overall performance. 2 measured with 2 23 -1 prbs at 156mb/s. (over operating case temperature. v cc = 3.13 to 3.47v) all parameters guaranteed only at typical data rate all parameters guaranteed only at typical data rate 2 21737-0972, rev.a 2009-01-14
oplink communications, in c. electrical pad layout host board connector pad layout toward bezel toward asic 20 19 18 17 16 15 14 13 12 11 1 2 3 4 5 6 7 8 9 10 20 19 18 17 16 15 14 13 12 11 tx gnd td- (tx data in-) td+ (tx data in+) tx gnd vcctx vccrx rx gnd rd+ (rx data out+) rd- (rx data out-) rx gnd top of board 1 2 3 4 5 6 7 8 9 10 tx gnd tx fault tx disable mod_def(2) mod_def(1) mod_def(0) no connection los rx gnd rx gnd bottom of board (as viewed thru top of board) transmitter performance characteristics TRCE03KE2C000C3 (over operating case temperature. v cc = 3.13 to 3.47v) parameter symbol minimum typical maximum units input voltage swing (td+ & td-) 1 v pp-dif 0.25 - 2.4 v input high voltage (tx disable) 2 v ih 2.0 - v cc v input low voltage (tx disable) 2 v il 0 - 0.8 v output high voltage (tx fault) 3 v oh 2.0 - v cc + 0.3 v output low voltage (tx fault) 3 v ol 0 - 0.8 v 1 diferential peak-to-peak voltage. 2 there is an internal 4.7 to 10k pull-up resistor to vcct. 3 open collector compatible, 4.7 to 10k pull-up resistor to vcc (host supply voltage). receiver electrical interface electrical power supply characteristics (over operating case temperature. v cc = 3.13 to 3.47v) parameter symbol minimum typical maximum units supply voltage v cc 3.13 3.3 3.47 v supply current i cc - 175 350 ma parameter symbol minimum typical maximum units output voltage swing (rd+ & rd-) 1 v pp-dif 0.6 - 2.0 v output high voltage (los) 2 v oh 2.0 - v cc + 0.3 v output low voltage (los) 2 v ol 0 - 0.5 v 1 diferential peak-to-peak voltage across external 100 load. 2 open collector compatible, 4.7 to 10k pull-up resistor to vcc (host supply voltage). (over operating case temperature. v cc = 3.13 to 3.47v) module definition mod_def(0) pin 6 mod_def(1) pin 5 mod_def(2) pin 4 interpretation by host ttl low scl sda serial module defnition protocol 3 21737-0972, rev.a 2009-01-14
oplink communications, in c. application notes electrical interface: all signal interfaces are compliant with the sfp msa specifcation. the high speed data interface is diferential ac-coupled internally with 1f and can be directly connected to a 3.3v serdes ic. all low speed control and sense output signals are open collector ttl compatible and should be pulled up with a 4.7 - 10k resistor on the host board loss of signal (los): the loss of signal circuit monitors the level of the incoming optical signal and generates a logic high when an insufcient photocurrent is produced. tx_fault: the output indicates low when the transmitter is operating normally, and high with a laser fault including laser end-of-life. tx fault is an open collector/drain output that should be pulled up with a 4.7 - 10k resistor on the host board. tx fault is latched per sfp msa. tx_disable: when the tx disable pin is at logic high, the transmitter optical output is disabled (less than -45dbm). serial identifcation and monitoring: the module defnition of sfp is indicated by the three module definition pins, mod_def(0), mod_def(1) and mod_def(2). upon power up, mod_def(1:2) appear as nc (no connection), and mod_def(0) is ttl low. when the host system detects this condition, it activates the serial protocol (standard two-wire i 2 c serial interface) and generates the serial clock signal (scl). the positive edge clocks data into the eeprom segments of the sfp that are not write protected, and the negative edge clocks data from the sfp. the serial data signal (sda) is for serial data transfer. the host uses sda in conjunction with scl to mark the startand end of serial protocol activation. the supported monitoring functions are internal temperature, supply voltage, bias current, transmitter power, average receiver signal, all alarms and warnings and software monitoring of tx fault/los. the device is internally calibrated. the data transfer protocol and the details of the mandatory and vendor specifc data structures are defned in the sfp msa, and sff-8472, rev. 9.4. power supply and grounding: the power supply line should be well-fltered. all 0.1f power supply bypass capacitors should be as close to the transceiver module as possible. example of sfp host board schematic TRCE03KE2C000C3 4 18 19 3 tx data in+ 15 1 h coil or ferrite bead ? (<0.2 series resistance) ? 0.1 tx data in- tx disable 16 0.1 + 10 50 line ? 1, 9,10,11,14,17,20 0.1 + 10 to 50 load ? vcc 3.3v rx data out+ 13 12 rx data out- 5 4 6 mod_def(0) mod_def(1) mod_def(2) los to 50 load ? 8 r 2 tx fault r r r vcc 3.3v 50 line ? 50 line ? 50 line ? r trce03 r: 4.7 to 10k cap values in f 21737-0972, rev.a 2009-01-14
46335 landing pkwy fremont, ca 94538 tel: (510) 933-7200 fax: (510) 933-7300 email: sales@oplink.com ? www.oplink.com oplink communications, inc. reserves the right to make changes in equipment design or specifcations without notice. information supplied by oplink commu - nications, inc. is believed to be accurate and reliable. however, no responsibility is assumed by oplink communications, inc. for its use nor for any infringements of third parties, which may result from its use. no license is granted by implication or otherwise under any patent right of oplink communications, inc. ? 2006, oplink communications, inc. dimensions in inches [mm] defaul tt olerances: .xxx = + .005?, .xx = + .01? mechanical package ordering information 1.49 [.059] 1.99 [.078] 10.45 [.411] 11.94 [.470] 8.46 [.333] 0.45 [.018] 0.60 [.024] 0.60 [.024] 13.62 [.536] 14.94 [.588] 45.00 [1.772] 13.80 [.543] 2.50 [.098] 6.54 [.257] 9.20 [.362] 41.80 [1.646] 6.25 [.246] 2.29 [.090] TRCE03KE2C000C3 model name operation temperature center wavelength (nm) link budget latch color TRCE03KE2C000C3 - 5c to +70c 1510 44db blue 5 21737-0972, rev.a 2009-01-14


▲Up To Search▲   

 
Price & Availability of TRCE03KE2C000C3

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X